National Chung Hsing University Institutional Repository - NCHUIR > 工學院 > 生醫工程研究所 > 依資料類型分類 > 期刊論文 >  Acute Response in vivo of a Fiber-Optic Sensor for Continuous Glucose Monitoring from Canine Studies on Point Accuracy

Please use this identifier to cite or link to this item: http://nchuir.lib.nchu.edu.tw/handle/309270000/131660

標題: Acute Response in vivo of a Fiber-Optic Sensor for Continuous Glucose Monitoring from Canine Studies on Point Accuracy
作者: Liao, K.C.;Chang, S.C.;Chiu, C.Y.;Chou, Y.H.
張仕杰;廖國智
關鍵字: in vivo glucose monitoring;fiber-optic sensor;point accuracy;Clarke;error grid analysis;calibration;loop insulin delivery;complications;design
日期: 2010
Issue Date: 2012-12-07 16:30:05 (UTC+8)
關連: Sensors, Volume 10, Issue 8, Page(s) 7789-7802.
摘要: The objective of this study was to evaluate the acute response of Sencil (TM), a fiber-optic sensor, in point accuracy for glucose monitoring in vivo on healthy dogs under anesthesia. A total of four dogs with clinically normal glycemia were implanted with one sensor each in the chest region to measure the interstitial glucose concentration during the ovariohysterectomy procedure. The data was acquired every 10 seconds after initiation, and was compared to the concentration of venous plasma glucose sampled during the surgery procedures for accuracy of agreement analysis. In the four trials with a range of 71-297 mg/dL plasma glucose, the collected 21 pairs of ISF readings from the Sencil (TM) and the plasma reference showed superior dispersion of residue values than the conventional system, and a linear correlation (the Pearson correlation coefficient is 0.9288 and the y-intercept is 14.22 mg/dL). The MAD (17.6 mg/dL) and RMAD (16.16%) of Sencil (TM) measurements were in the comparable range of the conventional system. The Clarke error grid analysis indicated that 100% of the paired points were in the clinically acceptable zone A (61.9%) and B (38.1%).
Relation: Sensors
Appears in Collections:[依資料類型分類] 期刊論文
[依教師分類] 廖國智
[依教師分類] 張仕杰
[依教師分類] 張仕杰

loading Web of Knowledge data....

Files in This Item:

File SizeFormat
index.html0KbHTML434View/Open


 


學術資源

著作權聲明

本網站為收錄中興大學學術著作及學術產出,已積極向著作權人取得全文授權,並盡力防止侵害著作權人之權益。如仍發現本網站之數位內容有侵害著作權人權益情事者,請權利人通知本網站維護人員,將盡速為您處理。

本網站之數位內容為國立中興大學所收錄之機構典藏,無償提供學術研究與公眾教育等公益性使用。

聯絡網站維護人員:wyhuang@nchu.edu.tw,04-22840290 # 412。

DSpace Software Copyright © 2002-2004  MIT &  Hewlett-Packard  /   Enhanced by   NTU/NCHU Library IR team Copyright ©   - Feedback